Abstract: In this paper, an analytical and simulation solution for touch mode Micro-electromechanical systems pressure sensor operating in harsh environment is proposed. The principle of the paper is to design, obtain analytical solution and compare the results with the simulation using finite elements analysis for a circular diaphragm deflection before and after touch point. By looking at MEMS devices, when the diaphragm starts touching the fixed electrode by applying loads, it will have a major effect on the overall performance of the device. Therefore, one should consider the effect of touch mode in the system to achieve good linearity, large operating pressure range and large overload protection at output. As of so far the effect of touch mode has not been evaluated efficiently in the literatures. The proposed touch mode MEMS capacitive pressure sensor demonstrated diaphragm with radius of 180 μ m , the gap depth of 0.5 μ m and the sensor exhibit a linear response with pressure from 0.05 Mpa to 2 Mpa.

Keywords: MEMS, Touch mode, capacitive pressure sensor; harsh environment, FEA, and circular diaphragm.

Received October 27, 2008; accepted May 17, 2009

Read 5663 times Last modified on Wednesday, 15 December 2010 03:07
Share
Top
We use cookies to improve our website. By continuing to use this website, you are giving consent to cookies being used. More details…